- Overview
- Technical data
- Accessories
- Certification
- Business data
- Download
Product advantages
☑ Single-phase SSR☑ SCR output,Suitable for resistive & inductive loads
3D model
Input Specifications
Control Voltage Range | 4-32VDC |
Must Turn-on Voltage | 4VDC |
Must Turn-off Voltage | 1VDC |
Maximum Input Current | 25mA(@32VDC) |
Output Specifications
TVS Breakdown Voltage Range | 456~504V |
Value of I2t | 1250A2s |
Load Voltage Range | 48V-280VAC |
Maximum Transient Overvoltage | 600Vpk |
Load Current Range | 0.1-40A |
Maximum Turn-on Time | 1/2cycle+1ms |
Maximum Surge Current (@10 ms) | 500A |
Maximum Off-State Leakage Current (@Rated Load Voltage) | 10mA |
Maximum On-State Voltage Drop (@Rated Current) | 1.7Vrms |
Minimum Off-State dv/dt @ Maximum Rated Voltage | 200V/μs |
General Specifications
Dielectric Strength (Input/Output,50/60Hz) | 4000Vrms |
Minimum Insulation Resistance (@500VDC) | 1000MΩ |
Ambient Temperature Range | -30℃~+80℃ |
Storage Temperature Range | -30℃~+100℃ |
Standards/Regulations
Standards/Regulations | GB/T 14048.5 |
EN/IEC 60947-5-1 |
Order number | 30010000327 |
Packing unit | 2 |
Minimum order quantity | 10 |
Products weight (without packaging) | 96g |
Data | |
---|---|
DRPG 20A-40A.pdf | Download |